<LOGO>
FM Transmitter Measurement Report
Created: 2024-09-06 02-35-07
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.50 MHz 5/5, 58 dBuV RIRE &
Pilot RDS Phase Difference
7.1 kHz 4.0 kHz 64 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
10 kHz 64 kHz 17100 0,0585
Modulation Power
Limit Measuring Tolerance
11,0 dBr 0,2 dBr
MIN AVE MAX % above 11,2 dBr
4,7 dBr 6,31 dBr 7,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RIRE & " F226 0 (No PTY) 1 0 1 2 2:35, 6.09.2024
RT
"RIRE : NICKELBACK "
AF EON
87.8, 88.7, 94.4, 95.4, 95.5, 96.2, 101.5 MHz -
FM Scope Station: 101.50 MHz, signal: 5/5 (58 dBuV) Max at: 64 kHz MIN: 10 kHz % above 75 kHz: 0,0585 Acquired: 2024/09/06 2:34:04 Total samples: 17100 Equivalent time: 0:14:15 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 7,5 dBr MIN: 4,7 dBr AVE: 6,31 dBr % above 11,2 dBr: 0,0 Last value: 6,2 dBr (2024/09/06 2:34:03) Station: 101.50 MHz, signal: 5/5 (58 dBuV) 02:22 02:24 02:26 02:28 02:30 02:32 02:34 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality